Electric range popped and sparked at the power cord in Valrico

Range made a popping sound, a small spark and a burning smell. Replaced the power cord, the terminal block and the wire harness with new connectors.

$99service call, credited to the repair
90 daysparts and labor warranty
8 to 4Monday to Friday
$125commercial service call
Repair request

Book a technician

This field is for validation purposes and should be left unchanged.
Name(Required)
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
What Type of Appliance(s) Do You Need Repaired?(Required)

$99 service call, credited to the repair. $125 for commercial units. Or call (813) 822-5910, Mon to Fri, 8 AM to 4 PM.

Work orderOct 12, 2026
Area
Valrico
Unit
Oven
Symptom
Range made a popping sound, a small spark and a burning smell
Found
The power cord had not been seated properly, so it arced and burned the terminal block and wiring
Outcome
Replaced the power cord, the terminal block and the wire harness with new connectors

Report by Sam Ralin, owner and senior technician

Burnt terminal block and power cord on an electric range
The burnt terminal block behind the range.
Arcing damage at the power cord connection of an electric range
Arcing damage at the cord connection.

A tenant in a Valrico rental heard a pop from the range, saw a small spark and smelled burning, and the property manager called us.

Behind the range, the technician found the cause. The power cord was not seated properly on the terminal block. A loose connection heats up every time the range draws power, and this one had arced until the terminal block and the wiring around it were burnt. He replaced the power cord, the terminal block and the wire harness, with new connectors.

If your range pops or smells like burning plastic

  • Turn it off and switch off its breaker.
  • Do not keep using it to see if it happens again.
  • Have the cord connection checked, especially if the range was recently moved or installed.

Recent job reports

All job reports
Whirlpool WGD5050 gas dryer in Tampa
Tampa, 33626Oct 2026

Whirlpool gas dryer not heating in Tampa 33626

Unit
Whirlpool dryer, WGD5050LW0
Symptom
Gas dryer tumbling but not heating
Found
A faulty igniter, plus a kinked exhaust vent hose restricting airflow
Outcome
Replaced the igniter and straightened the exhaust vent hose
Kenmore 110 series electric dryer in Lithia
LithiaOct 2026

Kenmore dryer screeching after the wrong parts were installed in Lithia

Unit
Kenmore dryer, 110.68133414
Symptom
Loud screeching, then the drum stopped turning
Found
An earlier repair had used a Samsung belt that was too short for this Kenmore, and it broke. Samsung rollers had also been fitted, and one was broken
Outcome
Installed the correct belt, replaced all drum support rollers with the right parts and added a new idler pulley
Drain pump inside a Scotsman SCN60PA ice machine
South TampaOct 2026

Scotsman ice machine drain pump running nonstop in South Tampa

Unit
Scotsman ice maker, SCN60PA-1SU
Symptom
Drain pump running continuously, black specks in the ice bin
Found
Faulty drain pump pressure switch and a damaged graphite auger bearing, caused by heavy mineral buildup
Outcome
Quoted a new pressure switch and auger bearing, plus descaling